SWP1
General specifications
SWP1-16MMF | SWP1-8MMF | SWP1-8 | ||
---|---|---|---|---|
Number of LAN ports (1000BASE-T/100BASE-TX/10BASE-T, etherCON connector) | 12 | 8 | 8 | |
Number of LAN ports (1000BASE-T/100BASE-TX/10BASE-T, RJ-45 connector) | 4 | - | - | |
Number of SFP ports (1000BASE-SX, opticalCON connector) | 2 (1 optical module is installed as standard) | 2 (1 optical module is installed as standard) | 2 (optical modules are not installed as standard) | |
Console port | 1 (RJ-45) | 1 (RJ-45) | 1 (RJ-45) | |
Automatic negotiation | Available | Available | Available | |
Auto MDI/MDI-X | Available | Available | Available | |
Switching capacity | 36 Gbit/s | 20 Gbit/s | 20 Gbit/s | |
Throughput | 27 Mpps | 15 Mpps | 15 Mpps | |
Maximum number of MAC addresses | 16,384 | 16,384 | 16,384 | |
Frame buffer | 1024 kB | 1024 kB | 1024 kB | |
VLAN | Port VLAN, Tag VLAN (IEEE802.1Q), Private VLAN | Port VLAN, Tag VLAN (IEEE802.1Q), Private VLAN | Port VLAN, Tag VLAN (IEEE802.1Q), Private VLAN | |
Maximum number of VLANs | 256 (VLAN ID 1-4,094) *VLAN ID 1 is the default VLAN ID. | 256 (VLAN ID 1-4,094) *VLAN ID 1 is the default VLAN ID. | 256 (VLAN ID 1-4,094) *VLAN ID 1 is the default VLAN ID. | |
IP multicast | IGMP Snooping (v1/v2/v3) | IGMP Snooping (v1/v2/v3) | IGMP Snooping (v1/v2/v3) | |
QoS | 8 egress queues, Policy-based QoS, Remarking (CoS, ToS, DSCP), Scheduling (SP, WRR) | 8 egress queues, Policy-based QoS, Remarking (CoS, ToS, DSCP), Scheduling (SP, WRR) | 8 egress queues, Policy-based QoS, Remarking (CoS, ToS, DSCP), Scheduling (SP, WRR) | |
Flow control | IEEE802.3x (Full-duplex), back pressure (Half-duplex) | IEEE802.3x (Full-duplex), back pressure (Half-duplex) | IEEE802.3x (Full-duplex), back pressure (Half-duplex) | |
Support functions | Storm control, HOL blocking prevention, Loop detection, ACL, SNMP agents, Link aggregation (IEEE 802.3ad LACP, Static), Spanning tree (STP*, RSTP*, MSTP), Port mirroring, Port shutdown, Link speed down shift, Packet counter, Power saving mode (IEEE802.3az EEE; Disabled in DANTE mode), DHCP client, Logging, Firmware download via TFTP/HTTP, Config file download via TFTP *STP and RSTP are supported via downward compatibility of MSTP. | Storm control, HOL blocking prevention, Loop detection, ACL, SNMP agents, Link aggregation (IEEE 802.3ad LACP, Static), Spanning tree (STP*, RSTP*, MSTP), Port mirroring, Port shutdown, Link speed down shift, Packet counter, Power saving mode (IEEE802.3az EEE; Disabled in DANTE mode), DHCP client, Logging, Firmware download via TFTP/HTTP, Config file download via TFTP *STP and RSTP are supported via downward compatibility of MSTP. | Storm control, HOL blocking prevention, Loop detection, ACL, SNMP agents, Link aggregation (IEEE 802.3ad LACP, Static), Spanning tree (STP*, RSTP*, MSTP), Port mirroring, Port shutdown, Link speed down shift, Packet counter, Power saving mode (IEEE802.3az EEE; Disabled in DANTE mode), DHCP client, Logging, Firmware download via TFTP/HTTP, Config file download via TFTP *STP and RSTP are supported via downward compatibility of MSTP. | |
DIP switches | CONFIG, VLAN PRESET | CONFIG, VLAN PRESET | CONFIG, VLAN PRESET | |
Indicators | Front: POWER, LED MODE×4, PORT×16×2*, SFP×2 *The LED MODE button allows the PORT lamps to be switched between indicating LINK/ACT-SPEED, STATUS, or VLAN. | Front: POWER, LED MODE×4, PORT×8×2*, SFP×2 *The LED MODE button allows the PORT lamps to be switched between indicating LINK/ACT-SPEED, STATUS, or VLAN. | Front: POWER, LED MODE×4, PORT×8×2*, SFP×2 *The LED MODE button allows the PORT lamps to be switched between indicating LINK/ACT-SPEED, STATUS, or VLAN. | |
Power supply (AC IN inlet) | AC100V-240V, 50/60Hz, Internal power supply (no power switch), Power supply inlet: locking type | AC100V-240V, 50/60Hz, Internal power supply (no power switch), Power supply inlet: locking type | AC100V-240V, 50/60Hz, Internal power supply (no power switch), Power supply inlet: locking type | |
Power supply (EXT DC INPUT inlet) | External power supply requirements: 24VDC±2V, 1A, XLR-4-32 type Connector | External power supply requirements: 24VDC±2V, 1A, XLR-4-32 type Connector | External power supply requirements: 24VDC±2V, 1A, XLR-4-32 type Connector | |
Maximum power consumption | 16 W, 0.29 A | 11 W, 0.21 A | 11 W, 0.21 A | |
Heat dissipation | 14.0 kcal/h | 9.5 kcal/h | 9.5 kcal/h | |
Chassis | Metal case, no fan | Metal case, no fan | Metal case, no fan | |
Hazardous substances management | RoHS compliant | RoHS compliant | RoHS compliant | |
Temperatura operacional | 0 to 40°C | 0 to 40°C | 0 to 40°C | |
Temperatura de armazenamento | -20 to 60°C | -20 to 60°C | -20 to 60°C | |
Dimensões | Largura | 480mm | 480mm | 480mm |
Altura | 44mm | 44mm | 44mm | |
D | 362mm | 362mm | 362mm | |
Peso | 4.6 kg | 4.2 kg | 4.2 kg | |
Accessories | Cabo de energia, manual do proprietário | Cabo de energia, manual do proprietário | Cabo de energia, manual do proprietário | |
N-Série | Estúdio de Mixagem Digital | MMF-SWP1 (unidade de expansão óptica), PA-700 (adaptador AC) | MMF-SWP1 (unidade de expansão óptica), PA-700 (adaptador AC) | MMF-SWP1 (unidade de expansão óptica), PA-700 (adaptador AC) |
INTERFACE SPECIFICATIONS
Terminal | Format | Level | Connector |
---|---|---|---|
1-8 *1 1-8,13-16 *2 *3 | IEEE802.3 | 10BASE-T/100BASE-TX/ 1000BASE-T |
etherCON CAT5e |
9-12 *2 *3 | IEEE802.3 | 10BASE-T/100BASE-TX/ 1000BASE-T |
RJ-45 |
9,10 *4 17,18 *5 *8 | IEEE802.3 | 1000BASE-SX | opticalCON |
CONSOLE (RS-232C) | – | RS-232C | RJ-45 *6 |
EXT DC INPUT | - | - | XLR-4-32 type *7 |
*2 SWP1-16MMF
*3 These terminals support AutoMDI/MDI-X
*4 The SWP1-8MMF supports the option for port 10, and the SWP1-8 supports the option for both ports 9 and 10
*5 The SWP1-16MMF supports the option for port 18
*6 For the pin assignments, refer to CONNECTOR PIN ASSIGNMENTS
*7 Pin 4=+24VDC, pin 1=GND, pins 2 and 3=N.C.
External power supply requirements: 24VDC±2V, 1A
*8 Conforming cable: GI-type multi-mode fiber cables with a core diameter /cladding diameter of approximately 50 μm/125 μm.
Maximum cable length: 300 m
CONNECTOR PIN ASSIGNMENTS
CONSOLE (RS-232C)Pin No. | Signal | ||
---|---|---|---|
1 | RTS | ||
2 | DTR | ||
3 | TxD | ||
4 | GND | ||
5 | GND | ||
6 | RxD | ||
7 | DSP*9 | ||
8 | CTS*9 |
Dante Mode & VLAN Preset Settings
- Common Settings to Dante Mode
QoS (Quality of Service)
Enabled
QoS Trust Mode
DSCP
DSCP to Queue (*1)
DSCP:56 -> 7, DSCP:46 -> 5, DSCP: 8 -> 2, Others -> 0
EEE (Energy Efficient Ethernet)
Disabled
- Preset Normal
Ports 1 to 8 (1 to 16)
Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
Ports 9/10 (17/18)
Access Port, VLAN 1, LAG On, STP On (*2), Loop Detection Off
VLAN 1 (for Dante)
IGMP Snooping: Enabled
Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
IPv4 Address: DHCP
- Preset A
Ports 1/2, 5/6 (1 to 6, 9/10, 13/14)
Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
Ports 3/4, 7/8 (7/8, 11/12, 15/16)
Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
Ports 9/10 (17/18)
Trunk Port, VLAN 1/2, LAG On, STP On (*2), Loop Detection Off
VLAN 1 (for Dante)
IGMP Snooping: Enabled
Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
IPv4 Address: DHCP
VLAN 2 (for Others)
IGMP Snooping: Disabled
- Preset B
Ports 1/2, 5 (1 to 6, 9/10, 13)
Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
Ports 3/4, 6 (7/8, 11/12, 14)
Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
Ports 7 to 10 (15 to 18)
Trunk Port, VLAN 1/2, LAG On, STP On (*2), Loop Detection Off
VLAN 1 (for Dante)
IGMP Snooping: Enabled
Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
IPv4 Address: DHCP
VLAN 2 (for Others)
IGMP Snooping: Disabled
- Preset C
Ports 1/2, 5/6, 9 (1 to 6, 9/10, 13/14)
Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
Ports 3/4, 7/8, 10 (7/8, 11/12, 15/16)
Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
VLAN 1 (for Dante Primary)
IGMP Snooping: Enabled
Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
IPv4 Address: DHCP
VLAN 2 (for Dante Secondary)
IGMP Snooping: Enabled
Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
* The port numbers in parentheses refer to those on SWP1-16MMF.
*1 The DSCP to Queue settings are optimized for Dante.
*2 In order to activate Spanning Tree protocol (MSTP), you need to turn off Link Aggregation on the corresponding ports. You can download the Config files with Spanning Tree enabled here.
Dante Mode & VLAN Preset Settings
Common Settings to Dante Mode
- QoS (Quality of Service)
- Enabled
- QoS Trust Mode
- DSCP
- DSCP to Queue (*1)
- DSCP:56 -> 7, DSCP:46 -> 5, DSCP: 8 -> 2, Others -> 0
- EEE (Energy Efficient Ethernet)
- Disabled
Preset Normal
- Ports 1 to 8 (1 to 16)
- Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
- Ports 9/10 (17/18)
- Access Port, VLAN 1, LAG On (sa1), STP On (*2), Loop Detection Off
- VLAN 1 (for Dante)
- IGMP Snooping: Enabled
- Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
- IPv4 Address: DHCP
- IGMP Snooping: Enabled
Preset A
- Ports 1/2, 5/6 (1 to 6, 9/10, 13/14)
- Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
- Ports 3/4, 7/8 (7/8, 11/12, 15/16)
- Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
- Ports 9/10 (17/18)
- Trunk Port, VLAN 1/2, LAG On (sa1), STP On (*2), Loop Detection Off
- VLAN 1 (for Dante)
- IGMP Snooping: Enabled
- Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
- IPv4 Address: DHCP
- IGMP Snooping: Enabled
- VLAN 2 (for Others)
- IGMP Snooping: Disabled
Preset B
- Ports 1/2, 5 (1 to 6, 9/10, 13)
- Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
- Ports 3/4, 6 (7/8, 11/12, 14)
- Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
- Ports 7 to 8 (15 to 16)
- Trunk Port, VLAN 1/2, LAG On (sa1), STP On (*2), Loop Detection Off
- Ports 9 to 10 (17 to 18)
- Trunk Port, VLAN 1/2, LAG On (sa2), STP On (*2), Loop Detection Off
- VLAN 1 (for Dante)
- IGMP Snooping: Enabled
- Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
- IPv4 Address: DHCP
- IGMP Snooping: Enabled
- VLAN 2 (for Others)
- IGMP Snooping: Disabled
Preset C
- Ports 1/2, 5/6, 9 (1 to 6, 9/10, 13/14)
- Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
- Ports 3/4, 7/8, 10 (7/8, 11/12, 15/16)
- Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
- VLAN 1 (for Dante Primary)
- IGMP Snooping: Enabled
- Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
- IPv4 Address: DHCP
- IGMP Snooping: Enabled
- VLAN 2 (for Dante Secondary)
- IGMP Snooping: Enabled
- Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
- IGMP Snooping: Enabled
* The port numbers in parentheses refer to those on SWP1-16MMF.
*1 The DSCP to Queue settings are optimized for Dante.
*2 In order to activate Spanning Tree protocol (MSTP), you need to turn off Link Aggregation on the corresponding ports. You can download the Config files with Spanning Tree enabled here.